Kenmore 116.23613 Vacuum Cleaner User Manual


 
TO REPLACE BELT
1. Install new
belt over motor
drive, then
over brush
sprocket.
NOTE: See
PARTS AND
FEATURES
for belt num-
ber.
End Cap
Motor
Brush Drive
Sprocket
2. Place agitator
assembly back
into Power-Mate ® .
Cover Base
4. Rotate
cover back.
Press cover
firmly until side
and rear tabs
snap into
place. Turn
Power-Mate ®
upside down
and replace
two (2) cover screws.
3. Line up
front of
cover and
base. Rest
cover on
frontedge
of base as
shown.
1. Remove Power-Mate ® cover as shown in
BELT CHANGING AND AGITATOR CLEAN-
ING section.
Push In ,_
And Turn
2. Push in and turn
bulb counterclock-
wise. then pull out
to remove.
Push In
And Turn
3. Push in and turn
bulb clockwise, to
replace. Bulb must
not be higher than
15 Watts(130 Volts).
4. Reinstall Power-Mate ® cover as shown in
BELT CHANGING AND AGITATOR CLEAN-
ING section.
NOTE: See PARTS AND FEATURES for
bulb number.
17