Karcher SHD-R 3000 Water Pump User Manual


 
English
SHD-R 3000
5.956-486 A2005937 (06/03)
A2
A. For your safety
5. Emergency drill
Turn mains supply voltage off at system
master switch.
Turn off supply of cleaning liquid.
If a handgun is being used, release any
remaining pressure in the system by
pressing the lever on the handgun.
6. Safety devices
Safety valve
!
Danger!
Injury hazard due to excessive pressure
within system. Do not adjust safety valve.
The safety valve has been preset and
sealed in the factory. Adjustments should
only be made by a Kärcher Customer
Service engineer.
7. Applicable regulations
Accident prevent regulations
Working with liquid sprayers BGV D15.
If water is used as the cleaning liquid:
Observe local regulations for disposal of
waste water.
Waste water should be directed into the
main drainage system in accordance with
local regulations.
If the water to be used is drawn from the
main supply network:
Install a mains disconnector to EN 1717
(e.g. float tank with float valve),
BetrSichV (industrial safety regulations).
If acids, alkaline solutions or solvents are to
be used:
Observe the legal requirements that are
currently applicable in your country. In
Germany the regulations of the industrial
employer's liability insurance
associations apply (BGI 504).
Observe instruction leaflets provided by
manufacturers of the detergent
concentrates that are to be used with this
system.
i
Important!
According to the UVV (accident prevention)
Guidelines (BGV D15, Art. 23), high-
pressure sprayers must be checked by an
expert with the initial startup and at least
every 12 months thereafter. Kärcher
Customer Service engineers are qualified to
carry out the prescribed tests on your
system.
The results of the test procedures must be
recorded in writing. A form into which the
test results can be entered is shown in
Chapter K: Test Record.