Karcher SHD-R 3000 Water Pump User Manual


 
English
SHD-R 3000
5.956-486 A2005937 (06/03)
E3
E. Care and maintenance
2. Maintenance schedule
Frequency Type of pump
SHD-R 3000
(F)
Action Procedure By whom?
Monthly
or after
every 160
operating
hours
Standard
S / SVA
Check pump for leaks If during operation more than
5 droplets per minute leak from
the pump, tighten piston seal
Operator
Standard
S
Lubrication Lubricate with 2 pump strokes of
grease gun per nipple
Operator
After
every 200
operating
hours
LM Oil change See Maintenance Tasks Operator
Six-monthly
or after
every 500
operating
hours
Standard
S / SVA
SLA
SSR
Oil change See Maintenance Tasks Operator
After
every 1000
operating
hours
all – Check and clean valves on pump
– Check piston
– Replace set of seals if required
– Oil change
– Check for correct functioning
Customer
service
Annually all Check tension of V-belt See Maintenance Tasks Operator
all Formal test Inspection in accordance with
Directive on "Working With
Liquid-spraying Devices"
Specialist