Glass Panel or Gasket Replacement
1. Wrap the new gasketing material evenly
around the edge of the glass, peeling
back the protective strip to expose the
adhesive as you go. Press the adhesive
side down onto the glass surface. Do not
stretch the gasket.
2. Place the gasketed glass within the
frame and press each of the retainer
clips back into place on the retainer
walls.
FOR REPLACEMENT, USEONLY
JØTUL CERAMIC GLASS PANEL
PART 220089. DO NOT USE ANY
OTHER TYPE OF GLASS WITH
THIS APPLIANCE.
Figure 32. Gasket Replacement