ITEM SPECIFICATION
Model Size 70 115 165
Output Rating (BTU / Hr) 70,000 115,000 165,000
Fuel Use only kerosene, #1/#2 diesel / fuel oil, JET A
or JP-8 fuels*
Fuel Tank Capacity
(U.S. Gal. / Liters) 5 / 18.9 9 / 34 13.5 / 51
Fuel Consumption
(Gal. Per Hr / Liters Per Hr) .52 / 1.97 .85 / 3.00 1.2 / 4.54
Pump Pressure (psi) 4.7 5.1 5.6
Electric Requirements 120V / 60 HZ 120V / 60 HZ 120V / 60 HZ
Amperage (Normal Run) 2.8 3.6 3.6
Motor RPM 3440 3400 3400
Hot Air Output (CFM) 360 490 575
Motor HP 1/8 1/5 1/5
Shipping Weight
(Approximate Pounds /
Kilograms) 36 / 16.3 56 / 25.4 71 / 32.2
Space heater Weight without Fuel
(Approximate Pounds /
Kilograms) 32 / 14.5 48 / 21.8 61 / 27.7
* Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter maintenance. Use in
extreme cold temperatures may require nontoxic anti-icer additives.
Specifications