20 Operator’s Manual
ITEM SPECIFICATION
Model Size AC-100LP
Output Rating (BTU / Hr) 65,000 85,000 100,000
Fuel Propane Vapor Only
Fuel Consumption:
(Gal. Per Hr / Liters Per Hr) 0.7 / 2.65 0.9 / 3.52 1.1 / 4.16
(Pounds Per Hr / Kilograms Per Hr) 3.0 / 1.36 3.9 /1.77 4.6 / 2.09
Supply Pressure to Regulator:
Minimum (for input adjustment) 10 PSI / 65.98 kPa
Maximum Tank Pressure
Regulator Outlet Pressure Factory Preset
Manifold Pressure 10" WC / 25.4 cm
Hot Air Output (Approx.) 475 CFM / 144.78 cubic meter/minute
Motor RPM 3200
Motor HP 1/10
Electric Input 120V / 60Hz
Amperage (Normal Run) 2.9
Ignition Continuous
Ignitor Gap 0.13 in / 0.15 in (3.3 mm / 3.8 mm)
Shipping Weight
(Approximate Pounds /
Kilograms) 29 / 13.15
Space Heater Weight
(Approximate Pounds /
Kilograms) 23 / 10.43
Specifications
RECORD SERIAL NUMBER
Write you model number, machine serial number and
date of purchase in the spaces provided below. Your
dealer needs this information when ordering parts.
Model No. ______________________________________________
Machine Serial No. _______________________________________
Date of Purchase ________________________________________
(To be filled in by purchaser)