12 Operator’s Manual
Installation
INSTALLATION
IMPORTANT: Review and understand the warnings in
the Safety Information section. They are needed to safely
operate this space heater. Follow all local ordinances and
codes when using this space heater.
WARNING: TEST ALL GAS PIPING AND
CONNECTIONS FOR LEAKS AFTER
INSTALLING OR SERVICING. NEVER
USE AN OPEN FLAME TO CHECK FOR
A LEAK. APPLY A MIXTURE OF LIQUID
SOAP AND WATER TO ALL JOINTS.
BUBBLES FORMING SHOW A LEAK.
CORRECT ALL LEAKS AT ONCE.
1. Provide propane supply system
(see Propane
Supply).
2. Connect fuel gas connector fitting on hose / regulator
assembly to Propane / L.P. tank(s). Turn counterclockwise
into threads on tank valve. Tighten firmly using wrench.
IMPORTANT: Tighten regulator with vent pointing down.
Pointing vent down protects regulator from weather
damage. (Fig. 1)
3. Connect hose to inlet connector. Tighten firmly using a
wrench. (Fig. 2)
IMPORTANT: Extra hose or piping may be used if needed.
Install extra hose or piping between hose/regulator
assembly and Propane / L.P. tank. You must use the
regulator supplied with heater.
4. Open propane supply valve on Propane / L.P. tank(s)
slowly.
Note: If not opened slowly, excess-flow check valve on
Propane / L.P. tank will stop gas flow. If this happens,
close propane supply valve and open again slowly.
5. Check all connections for leaks.
6. Close propane supply valve.
Hose
Regulator
Vent (pointing
down)
Supply
Valve
Propane
Tank
Fuel Gas
Connector
(Fig. 1)
Hose
Inlet Connector
(Fig. 2)
Operation
OPERATION
WARNING: FOLLOW THE MINIMUM FRESH,
O U T S I D E A I R V E N T I L AT I O N
REQUIREMENTS. IF PROPER FRESH,
OUTSIDE AIR VENTILATION IS NOT
PROVIDED, CARBON MONOXIDE
POISONING CAN OCCUR. PROVIDE
PROPER FRESH, OUTSIDE AIR
VENTILATION BEFORE RUNNING
HEATER.
START SPACE HEATER:
1.
Follow all ventilation and safety information.
2. Place the space heater in an area that provides
maximum circulation of the heated air. Follow all location
requirements noted in
the Safety Information.