Ingersoll-Rand 7940-8770 Home Security System User Manual


 
75.5255.02 XXXXXXXX
7940-8770 LCN Page 7 of 11
PROGRAMMING
GUIDE – PATTERN
ADJUSTMENTS
NOTE
: THRESHOLD: The Threshold is always OFF when the door is closed.
NOTE
: PATTERN WIDTH OR DEPTH: When pattern width or depth is changed, a setup of the new
pattern size will automatically be triggered once a value key has been pressed.
Pattern Width
Door Open or
Closed
1: Wide (closed door)
2 : Middle (open door)
3 : Asymmetric Left Narrow
4 : Asymmetric Right Narrow
5 : Narrow Left
6 : Narrow Right
7 : Asymmetric Left Wide
8 : Asymmetric Right Wide
9 : Center Narrow
See Note: Pattern Width or Depth
Pattern Depth
1: Deep – Threshold ON
2 : Medium – Threshold ON (open)
3 : Limited – Threshold ON
4 : Deep – Threshold OFF
5 : Medium – Threshold OFF (closed)
6 : Limited – Threshold OFF
See Note: Threshold
See Note: Pattern Width or Depth
Sensitivity
Door Open-Closed
0 (min) 9 (max) (default 7 for
door open, default 6 for door
closed)
Immunity
1: Normal
2 : Rain Mode
3 : Snow Mode
Automatic Learn
Time
0: 30 seconds
1: 1 minute
2: 2 minutes
3: 3 minutes
4: 5 minutes
5: 7 minutes
6: 10 minutes
7: 15 minutes
8: 10 seconds
9: Infinity – no learn