Ingersoll-Rand 650453-X Water Pump User Manual


 
OPERATOR’S MANUAL
650453-X
RELEASED: 10-24-92
REVISED: 1-6-03
(REV. G)
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
ALSO INCLUDE MANUALS: 6544X-X (PN 97999-64) AIR MOTOR & S-632 GENERAL INFORMATION
MANUAL (PN 97999-624)
650453-X
2-BALL BASIC PUMP
4-1/4” AIR MOTOR
9:1 RATIO
4” STROKE
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
SERVICE KITS
Use only genuine AROR replacement parts to assure compatible
pressure rating and longest service life.
61268 for repair of air motor section.
637177 for repair of lower pump end of models 650453-5 and
650453-11.
Order lower pump end service parts separately for models
650453-7, 650453-8, 650453-9 and 650453-10.
GENERAL DESCRIPTION
The ARO9:1 ratio basicpumpassemblyconsists ofa 4-1/4” air mo-
tor, spacersection and two-balllower pump end. The4-1/4” air mo-
tor is a reciprocating type with pneumatic control circuit and
reversing valve. No working springs or piston connected trip rods
are used to reverse the air motor piston.
SPACER SECTION
Theair motorisconnectedtothe lowerpumpendwith aspacer tube
and solvent cup. This allows for lubrication of the upper packing
gland and to prevent air motor contamination because of normal
wear and eventual leakage through the material packing gland.
LOWER PUMP END
Thetwo-balldesignprovides foreasypriming ofthelowerfoot valve
and the double acting feature is standard in all ARO industrial
pumps. Material is delivered to the pump discharge outlet on both
the up and down stroke.
RATIOXREGULATEDAIRPRESSURETOAIRMOTOR=MAXIMUM
FLUID PRESSURE.
The9:1ratio isonexpression oftherelationshipbetween theairmo-
torarea andthe lowerpump endarea. When150p.s.i. (10.3bar)air
pressure issupplied to the air motor, the lowerpump end willdevel-
opamaximumof1,350p.s.i.(93.1bar)fluidpressure(atnoflow).As
thefluid controlisopened, theflowrate willincrease astheairmotor
cycle rate increases to keep up with the demand.
OPERATING PRECAUTIONS
DO NOT exceed maximum working pressure of 1,350 p.s.i. (93.1
bar) at 150 p.s.i. (10.3 bar) air inlet pressure. HEED ALL WARN-
INGS.
WARNING: HIGH PRESSURE DEVICE. Improper usage of
this equipmentcould result in serious injury.The possibility of injec-
tion into the flesh is a potential hazard. Never allow any part of the
human body tocome in front ofor in direct contact with the material
outlet. An injection injury can be serious. If injection should occur,
contact a qualified physician immediately for treatment.
COMPONENT RUPTURE.This pump is capable of producinghigh
material pressure as stated on pump model plate.
Be surematerialhoses andothercomponents areableto withstand
fluid pressures developed by this pump.
PUMP DATA
FIGURE 1
NOTE: Dimensionsareshownininchesand(mm),suppliedforreferenceonlyandare
typically rounded up to the nearest 1/16 inch.
MODELS 650453-X
Air Inlet (female)
1/2 - 14 N.P.T.F. - 1
65445-B Air Motor
(see 6544X-X manual)
Material Outlet (female)
3/4 - 14 N.P.T.F. - 1
“A”
“B”
“C”
Model
Number
Packing
Material
Pump
Type
“A” “B” “C”
650453-5 PTFE 55 gal 59-1/4” 37-1/8” Immersed
650453-7 PTFE/Leather Stub 32 -11/16” 10-9/16” 1-1/2” NPT
650453-8 UHMW-PE 55 gal 59-1/4” 37-1/8” Immersed
650453-9 UH / Leather Stub 32-11/16” 10-9/16” 1-1/2” NPT
650453-10 UHMW-PE Stub 32-11/16” 10-9/16” 1-1/2” NPT
650453-11 PTFE Stub 32-11/16” 10-9/16” 1-1/2” NPT
www.ingersollrandproducts.com
E2010
(800) 495--0276 D FAX (800) 892--6276
INGERSOLL RAND COMPANY
209 NORTH MAIN STREET -- BRYAN, OHIO 43506
CCN 81496986