Hunter Fan UH68ODH Electric Heater User Manual


 
UH68ODK Tent Heater
PMCS Procedures
1.1 Fuel Line System - check all fuel lines and fittings for leaks. Make sure vent at top Suction
Feed Adapter is clear of ice and snow.
1.2 Exhaust stack - make sure exhaust stack is clear of ice and snow. Check for damage or
anything that might obstruct the flow of exhaust gas.
1.3 Fuel Supply – before filling, check for water or dirt at the bottom of the can. Fill can before
operation. Heater will operate for about 9 hours with full can. Check at regular intervals to
avoid running dry.
1.4 Electrical connections - check cord for nicks or cuts, make sure cord is securely plugged
in to power supply
1.5 Remote Control Panel – check cord for nicks or cuts. Check overall condition of control
box
1.6 Pop Up Duct Adapter – check for cuts in fabric. In the field, repair cuts with duct tape.
Cuts may be sewn shut. If cut is too large to be sewn shut, replace entire fabric interface.
1.7 Ducts - check for cuts in fabric. In the field, repair cuts with duct tape. Cuts may be sewn
shut. If cut is too large to be sewn shut, replace entire duct.
1.8 Sediment Bowl – check for dirt and water. Clean if necessary.
1.9 Carburetor, Burner Head – use the following procedure to service the carb and burner
head:
Check carb bowl
for water, dirt,
and varnish
Look for carbon
deposits in this area.
Check for carbon on
igniter.
Check mixer for
dirt and carbon
deposits
3-2