Hunter Fan UH68ODH Electric Heater User Manual


 
UH68 ODK/ODH Tent Heater
2-10
Operation Under Rainy Conditions
1. The remote control panel is water-resistant. No
special instructions for setting up in the rain.
2. Do not remove protective covers from the
remote and power receptacles until ready to
connect.
3. To keep rain water from collecting around
heater, place heater on skid (1), bricks or small
logs. Make sure heater is stable.
4. Paint all chipped and scratched surfaces to
prevent rust
Strike Procedure
1. Drain fuel lines
1. While heater is burning, open drain cock (1) on fuel supply line. Let heater run until
you hear combustion stop. (burner)
2. Move main switch to OFF and allow heater to cool.
3. Close drain cock (1) on supply line. Using a rag or fuel absorbent mat remove supply
line from heater at QD fitting. Make sure to hold rag beneath heater QD fitting to
catch any fuel left in the fitting.
4. Attach heater QD cover (2).
5. Hold supply line (3) above fuel can and open drain cock (1). Raise as high as
possible to let fuel drain into fuel can.
6. Close drain cock (1) and detach supply line from suction feed adapter. Coil up
supply line and connect both ends together (4) to keep out dirt.
7. Disconnect overflow line and coil up. Attach QD cover (2)
2. Disconnect ducts (6) and clamps (5), store separate from the heater.(* see duffle bag
option for storage)
3. Remove stack, fold PUDA fabric (7) and close PUDA leaving doors open.
BEFORE PROCEDING MAKE SURE HEATER IS COOLED DOWN AND
DISCONNECTED FROM POWER SUPPLY
1