19
ATTACHING THE THERMOSTAT
Lift the thermostat cover and set the SYSTEM switch to OFF and
the FAN switch to AUTO.
1.
Fan option - Locate the HE/HG switch on the back of the
thermostat. Set the switch to HG (default) for gas furnace
and oil burners. Set the switch to HE for electric furnaces. (The
switch has no effect when the system is set to cooling mode.)
2. Recovery - Locate the Auto Recovery switch on the back of
the thermostat. If you wish to use the Energy Star compliant
Auto Recovery feature, verify that the switch is in the ENABLE
position. If you do not wish to use this feature, simply change
the switch to the DISABLE position. See pages 44-45 for more
information.
3.
System type - Locate the System Type switch on the
back of the thermostat. Select either STD (Standard) or HP
(Heat Pump) to match your system.
INSTALLING THE THERMOSTAT, CONT.