Hotpoint HAG 51 K Burner User Manual


 
8
GB
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
V
I
Fig.E Fig.F
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used.
This sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or
vary) from the recommended pressure, it is necessary
to fit a suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative
to “regulators for channelled gas”.
Burner and Nozzle
Specification
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
52TGW
HAL 51 P
HAG 51 P
HAG 51 K
HAG 51 X
HAG 51 G
S
S
R
A
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
(mm) Nominal Reduced (mm) (mm) *** ** (mm)
Fast
(Large)(R)
100 94 2,60 0,7 41 80 189 186 118 286
Semi Fast
(Medium)(S)
75 69 1,90 0,4 30 70 138 136 104 181
Auxiliary
(Small)(A)
51 46 1,00 0,4 30 52 73 71 76 95
Oven - 2,60 0,6 36 71 189 186 115 248
Grill - 2,50 1,3 63 80 182 179 122 238
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25