Honeywell UV100RM Air Conditioner User Manual


 
UV100RM TRUEUV™ COIL TREATMENT SYSTEM
68-0297EFS—05 2
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
SPECIFICATIONS
TRADELINE® Models Available
The UV100RM1 TrueUV Coil Treatment System is duct-
mounted at the air conditioner coil of an HVAC system. It
helps prevent mold and mildew from forming on the air
conditioner coil and drain pan which can lower the efficiency
of the cooling system and can allow unwanted odors into the
home.
UV100RM1 includes the UC10W1 bulb, handle, base, ballast,
cord connections, adjustable mounting bracket, shield,
indicator window and mounting screws.
UC10W1 Replacement 10 watt UV-C bulb.
Efficiency: UV100RM TrueUV kills up to 99% of mold on
cooling coils.
- Test performed in a test duct showed reduction in Aspergil-
lus-Niger when surface as irradiated at a distance of 18
inches for three hours in still air using new lamps.
Electrical Ratings
Voltage Rating: 24Vac, 50/60 Hz.
Class 2 device 30V, max
Input Current Rating: 750mA
Input Power Rating: 18W max, 15W nominal, 15VA
Bulb Rating: 10W, 220mA
Temperature Ratings
Bulb Temperature Range (in moving air): 40 to 170F
Ballast Ambient Temperature Range: 30 to 125F
Shipping Temperature Range: -30 to 150F
Relative Humidity: Up to 95% RH, non-condensing
Switch: CYCLE runs 3 hours on/3 hours off
Dimensions: See Fig. 1
Accessories: AT40A1162 NEMA Standard Universal Trans-
former (not included).
Approvals:
Underwriters Laboratories Inc. listed.
Duct-mounted germicidal lamp assembly.
The health aspects associated with the use of this product and
its ability to aid in disinfection of environment air have not
been investigated by UL.
Fig. 1. Dimensions in in. (mm).
SAFETY PRECAUTIONS
Please read before installing or servicing product.
14-61/64 (380)
2-3/4 (70)
1-13/16
(47)
16-11/16 (424)
M27054
3-5/32
(80)
1-1/2 (38)
2-3/4 (74)
4-3/32
(104)
M27056
1-11/32
(34)