Setup functions (factory default setting listed, other options available)
384 Dehumidification fan control Forces fan on
390 Dehumidification away mode Off
391 Away mode fan operation Automatic
392 Away mode low temp. setting 76° F (24.5° C)
393 Away mode high temp. setting 85° F (29.5° C)
394 Away mode dehumidification 65% relative humidity
500 Reminder: Furnace filter Off
502 Furnace filter runtime counter Count heat and cool
510 Reminder: Humidifier pad Off
520 Reminder: UV bulb Off
530 Adaptive Intelligent Recovery On
540 Number of schedule periods 4
580 Minimum compressor off time 5 minutes
600 Maximum heat range 90° F (32° C)
610 Minimum cool range 60° F (15.5° C)
630 Minimum compressor off time Off
640 Clock format 12-hour
650 Extended fan on time (heat) Off
660 Extended fan on time (cool) Off
670 Keypad lock Unlocked
680 Temp. control (heat) Standard
690 Temp. control (cool) Standard
700 Temperature display offset No offset
701 Humidity display offset No offset
702 Outdoor temp. display offset No offset
703 Outdoor humidity display offset No offset
710 RESTORE FACTORY DEFAULTS No
Customer contact information (optional, but recommended)
1100 Dealer name Your company name
1150 Dealer phone number Your telephone contact
1200 Dealer email address Your email address
1250 Dealer website Your web site
Installer setup tables