Honeywell TH5220D Thermostat User Manual


 
FocusPRO
TH5220D Non-programmable Digital Thermostat
17
In case of difficulty
“Cool On” or
“Heat On”
is flashing
Compressor protection timeout is engaged. Wait 5 minutes for the
system to restart safely, without damage to the compressor.
Heating equip-
ment is running
in cool mode
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating/cooling equipment (see page 11).
Cannot change
system setting
to “Heat”
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating equipment (see page 11).
Change Installer Setup, Function 12 (System Setting) to Manual
or Auto
Changeover (see page 12).
Cannot change
system setting
to “Cool”
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed cooling equipment (see page 11).
Change Installer Setup, Function 12 (System Setting) to Manual
or Auto
Changeover (see page 12).
“Heat On” is
not displayed
Change the System Setting to Heat
, and set the temperature level above
the current room temperature.
“Cool On” is not
displayed
Change the System Setting to Cool, and set the temperature level below
the current room temperature.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Battery holder ......................................................Part Number 50007072-001
Cover plate assembly ........................................Part Number 50002883-001
(Use to cover marks left by old thermostats.)
Specifications
Temperature Ranges
Heat: 40° to 90°F (4.5° to 32°C)
Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
32° to 120°F (0° to 48.9°C)
Shipping Temperature
-20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
5% to 90% (non-condensing)
Physical Dimensions
3-9/16” H x 5-13/16” W x 1-1/2” D
91 mm H x 147 mm W x 38 mm D
Electrical Ratings
Terminal Voltage (50/60Hz) Running Current
W (O/B) Heating 20-30 Vac 0.02-1.0 A
(Powerpile) 750 mV DC 100 mA DC
W2 (Aux) Heating 20-30 Vac 0.02-0.5 A
Y Cooling 20-30 Vac 0.02-1.0 A
Y2 Cooling 20-30 Vac 0.02-1.0 A
G Fan 20-30 Vac 0.02-0.5 A
E Emergency heat 20-30 Vac 0.02-1.0 A
L Heat pump reset 20-30 Vac 0.02-0.5 A