SPECIFICATIONS • ORDERING INFORMATION
Ordering Information
When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the
TRADELINE Catalog or price sheets for complete ordering number, or specify—
1. Model number. 3. System, fan switching desired.
2. Number of heat and cool stages desired. 4. Application.
If you have additional questions, need further information or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Satisfaction
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9. International
Sales and Service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany,
Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
Specifications
IMPORTANT: The specifications given in this publi-
cation do not include normal manufacturing toler-
ances. Therefore, this unit may not exactly match
the listed specifications. Also, this product is tested
under closely controlled conditions, and some mi-
nor differences in performance can be expected if
those conditions are changed.
TRADELINE
®
MODELS
TRADELINE models (see Table 1) are selected and
packaged to provide ease of stocking and handling
and also maximum replacement value.
LIGHT-EMITTING DIODE (LED): SYSTEM LED
lights during thermostat ON cycle.
VOLTAGE RATING: 15 to 30 Vac.
CURRENT RATING: 1.6A maximum total per stage.
OPERATING HUMIDITY RANGE: 5 to 90 percent
relative humidity, noncondensing.
OPERATING AMBIENT TEMPERATURE RANGE:
40° F to 110° F [4° C to 43° C].
TABLE 1—TRADELINE MODELS.
SETPOINT RANGE: 45° F to 88° F [7° C to 31° C].
CALIBRATION: Self-calibrating thermostat and
thermometer to ±1° F.
SHIPPING TEMPERATURE: -20° F to +120° F [-29° C
to +49° C].
CYCLES PER HOUR ADJUSTMENT:
Heating: First stage of 2-stage heat models—fixed at
3 cph. Second stage of 2-stage heat models or heat
stage of single-stage heat models—factory-set at
6 cph; field-adjustable to 1,3,6 or 9 cph.
Cooling: Factory-set at 3 cph (not field adjustable);
minimum off-time of five minutes.
FINISH: Beige matte with decorative brushed metal
faceplate or Premier White™.
DIMENSIONS: Thermostat (mounted on subbase)—7 in.
[178 mm] long, 5-5/16 in. [135 mm] high, 1-3/4 in.
[44 mm] deep. See Fig. 1 for subbase dimensions.
TYPICAL KEYPAD: See Fig. 2.
ACCESSORIES:
TG586A Locking Cover.
TG512 Versaguard™ Universal Thermostat Guard.
Thermostat
Model
Stages Changeover Switching
Number
Heat Cool
Type
System Fan
Application
T8624C 2 1 Auto HEAT-AUTO-COOL-OFF ON-AUTO Multistage
T8624D 2 2 Auto HEAT-AUTO-COOL-OFF ON-AUTO Multistage
T8624D 2 2 Manual HEAT-OFF-COOL ON-AUTO Multistage