Step 11. Configure Installer Setup (Cont)
13. If you do not have a number 0190 on the left side of
your display, go to the next page.
14. If you have a number 0190 on the left side of your
display, press the Up or Down arrow to select your
setting for Installer Setup Number 0190.
15. After you select your setting, press the Next button
to go to the next Installer Setup Number.
M22310
0190 Heat Pump
Changeover
Valve
0 - Changeover Valve in Cooling --
Use this setting if you connected a
wire labeled O to the O/B terminal.
1 - Changeover Valve in Heating --
Use this setting if you connected a
wire labeled B to the O/B terminal.