Honeywell RTH6450D1009/E1 Thermostat User Manual


 
19
Troubleshooting
Heating or cooling
system does not
respond
Press SYSTEM button to set system to Heat. Make sure the temperature is
set higher than the Inside temperature.
Press SYSTEM button to set system to Cool. Make sure the temperature is
set lower than the Inside temperature.
Check circuit breaker and reset if necessary.
Make sure power switch at heating & cooling system is on.
Make sure furnace door is closed securely.
Wait 5 minutes for the system to respond.
“Cool On” or
“Heat On” is
flashing
Compressor protection feature is engaged. Wait 5 minutes for the system to
restart safely, without damage to the compressor.
Heat pump issues
cool air in heat
mode, or warm air
in cool mode
Check Function 2: Heat Pump Changeover Valve to make sure it is properly
configured for your system
Heating and
cooling equipment
running at the
same time (or heat
does not turn off)
Check Function 1: System Type to make sure it is set to match your heating
and cooling equipment.
Grasp and pull thermostat away from wallplate. Check to make sure bare
wires are not touching each other.
Heating system
is running in cool
mode
Check Function 1: System Type to make sure it is set to match your heating
and cooling equipment
For assistance with this product, please visit http://yourhome.honeywell.com or