19
Troubleshooting
Heating or cooling
system does not
respond
• Press SYSTEM button to set system to Heat. Make sure the temperature is
set higher than the Inside temperature.
• Press SYSTEM button to set system to Cool. Make sure the temperature is
set lower than the Inside temperature.
• Check circuit breaker and reset if necessary.
• Make sure power switch at heating & cooling system is on.
• Make sure furnace door is closed securely.
• Wait 5 minutes for the system to respond.
“Cool On” or
“Heat On” is
flashing
• Compressor protection feature is engaged. Wait 5 minutes for the system to
restart safely, without damage to the compressor.
Heat pump issues
cool air in heat
mode, or warm air
in cool mode
• Check Function 2: Heat Pump Changeover Valve to make sure it is properly
configured for your system
Heating and
cooling equipment
running at the
same time (or heat
does not turn off)
• Check Function 1: System Type to make sure it is set to match your heating
and cooling equipment.
• Grasp and pull thermostat away from wallplate. Check to make sure bare
wires are not touching each other.
Heating system
is running in cool
mode
• Check Function 1: System Type to make sure it is set to match your heating
and cooling equipment
For assistance with this product, please visit http://yourhome.honeywell.com or