Fig. 7—Thermometer adjustment.
INSERT AND TURN
SCREWDRIVER
BACKSIDE OF
FLIP-UP COVER
THERMOMETER
SLOT
M1810
Remove thermostat cover and open the flip-
up cover.
Set the thermostat cover on a table near
thermometer of known accuracy.
Allow at least five minutes for cover
thermometer to sense area temperature, then
compare the readings. Be careful not to touch
thermometer or breathe on it.
If the readings are the same, replace cover
and put the system into operation.
If the readings are different, insert a small
screwdriver in the thermometer slot, shown in
Fig. 7, and turn it until both thermometers
read the same.
Replace thermostat cover and put the
system into operation.