Honeywell Q682A Thermostat User Manual


 
10 69-0636—1
You can set up to six temperature changes
with the pins supplied. We recommend at least
five hours for each energy savings period.
To change the pins or add a new energy
savings period—
To insert a pin, push it straight into the
selected notch on the program dial until it is
completely seated.
To remove a pin, press against program
dial and pull the pin straight out. DO NOT
attempt to change a pin if it is engaged with
the program index wheel.
On heating-cooling systems, you must
remove the program pins from the heating
program to set new times for your cooling
program. Write down your colors and time
for reprogramming at the next heating
season. Also, you may want to change the
temperature setting lever positions.
Setting the Heating Program
Decide when you want the temperature to
reach the comfort level. Find the notch on the
program dial that is one-half hour before this
time and insert a red pin. The half-hour head
start gives the furnace time to heat the house
before you wake up or arrive home.
WINTER SUMMER
TEMPERATURE
PROGRAM
PIN IN
CONTROL
NIGHT
ENERGY
SAVING
PERIOD
DAY
ENERGY
SAVING
PERIOD
BEGINS
10:00 PM
ENDS
6:00 AM
BEGINS
7:30 AM
ENDS
4:00 PM
TEMPERATURE
PROGRAM
PIN IN
CONTROL
°C
27
24
27
24
RED
BLUE
RED
BLUE
°F
58
68
58
68
°C
14
20
14
20
°F
80
75
80
75
BLUE
RED
BLUE
RED
M8677
1
1 NOT APPLICABLE ON HEATING-ONLY MODEL.
Fig. 5— Program examples.