Honeywell Q682A Thermostat User Manual


 
15 69-0636—1
Troubleshooting (continued)
If Troubleshooting section has not solved the problem, call a qualified service technician or
Honeywell Customer Assistance Center at 1-800-468-1502, Monday - Friday, 7:00 AM to 5:30 PM,
Central time, for additional assistance.
Problem Check Action
No cooling
(
continued).
Y and R thermostat connections. Turn Off power to cooling system. Check for
correct terminal hookups. Repair any frayed
or broken wires. Firmly tighten all terminal
screws.
other problems. Contact a qualified service technician for
assistance.
Timer is losing time. batteries. May be dead. Replace with two new AAA alkaline batteries
as shown on page 7.
Thermostat setting
and thermometer
level position of thermostat. Reinstall thermostat subbase. Use a spirit
level.
reading disagree.
area around thermostat for drafts
or radiant heat.
Thermostat should be about 5 ft (1.5m)
above floor on an inside wall. Contact
qualified service technician for change of
location.
calibration of thermometer. See instructions on page 16.