Honeywell K14114 3/06 Rev.B Home Security System User Manual


 
- 71 -
INCOMING
PHONE
LINE
TO HANDSET
PHONE
LINE
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
PREMISES
TELEPHONE
1
2
3
4
865
7
PHONE
SOUNDERS
PLCD
AC
K10145X10 PLUG-IN
TRANSFORMER
9VAC, 25VA
EARTH
GROUND
EARTH
GROUND
INCOMING
TELEPHONE
LINE
RING
TIP
RING
TIP
( )
( )
(+)
(+)
( )
TO 24HR 110VAC
UNSWITCHED
OUTLET
TO 24HR 110VAC
UNSWITCHED
OUTLET
PIEZO
6-14VDC
120mA max.
(e.g. WAVE2EX)
6-14VDC
30mA max.
DATA
OUT
SYNC
IN
POWERLINE
CARRIER DEVICES
GND
RJ11
8
POSITION
JACK
AC
AC
SYNC
COM
DATA
11
10
12
15
16
13
14
9
BELL
07000-016-V1
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE
HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PROTECTION
ASSOCIATION STANDARDS ANSI/NFPA 70 NATONAL
ELECTRIC CODE AND NFPA 72 NATIONAL FIRE ALARM
CODE, CHAPTER 2 (NATIONAL FIRE PROTECTION ASSOC.,
BATTERYMARCH PARK, QUINCY, MA 02269). PRINTED
INFORMATION DESCRIBING PROPER INSTALLATION,
EVACUATION PLANNING AND REPAIR SERVICE IS TO BE
PROVIDED WITH THIS EQUIPMENT.
X10 ONLY
CONNECTIONS
FCC ID: CFS8DLLYNXREN-3
(LYNXR-I) COMPLIES WITH FCC
RULES, PART 68 FCC
REGISTRATION
No. 5GBUSA-25623-AL-E RINGER
EQUIVALENCE: 0.6B
NOTE
USE ONLY THE K10145X10 OR
K10145CN CLASS 2
TRANSFORMERS
PROVIDED
LYNXR-I SUMMARY OF CONNECTIONS
LOCAL
SOUNDER
DISABLE
SHUNT
REMOVE
TO DISABLE
LYNXR-I ALSO COMPLIES WITH THE FOLLOWING:
CANADIAN STANDARDS ASSOCIATION (CSA)
C22.1, CANADIAN ELECTRICAL CODE, PART 1,
SAFETY STANDARD FOR ELECTRICAL
INSTALLATIONS AND CAN/ULC-S540
INSTALLATION OF RESIDENTIAL FIRE
WARNING SYSTEMS.
THE LYNXR-I CONTROL IS COMPATIBLE WITH
THE FOLLOWING INTEGRAL RECHARGEABLE
BATTERY PACKS:
EXTERNAL SOUNDERS AND
POWERLINE CARRIER
DEVICES HAVE NOT BEEN
EVALUATED BY UL.
FUTURE USE
FUTURE USE
GND
SOUNDERS
PLCD
AC
GND
REPLACE EVERY FOUR YEARS
P/N LYNXRCHKIT-SC
P/N LYNXRCHKIT-HC
P/N LYNXRCHKIT-SHA
STANDARD/HIGH
CAPACITY BATTERY
CONNECTOR
ALARMNET LRR/IP
COMMUNICATIONS PORT
SUPER HIGH CAPACITY
BATTERY CONNECTOR
DATA IN
DATA OUT
UL INSTALLATIONS
THE MINIMUM WIRE
SIZE USED FOR
TELEPHONE
INSTALLATIONS
MUST BE #26 GAUGE
WARNING:
TO PREVENT RISK OF
SHOCK DISCONNECT
TELEPHONE LINE AT
TELECOM JACK BEFORE
SERVICING THIS UNIT.
INTERNAL 7845i-L*
MODULE ONLY
*WHEN AVAILABLE
1 2 3 4
BLACK
RED
YELLOW
GREEN
PL513
POWERLINE
INTERFACE
(IF USING
X10 DEVICES)
4-WIRE MODULAR PHONE
CORD WITH FLYING LEADS
K10145CN PLUG-IN
TRANSFORMER
9VAC, 25VA
9
15
16
13
14
FOR CANADIAN INSTALLATIONS
Notes: Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the
approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police
emergency number.
The System must be checked by a qualified technician once every three years.