TrueDryDR90/DR120DehumidicationSystem69-2690EFS—04 13
Technical Description
TrueDRY DR90/DR120 uses a refrigeration system similar
to an air conditioner to remove heat and moisture from
incoming air and add heat to the air that is discharged.
Hot, high-pressure refrigerant gas is routed from the
compressor to the condenser coil. The refrigerant is
cooled and condensed by giving up its heat to the air that
is about to be discharged from the unit. The refrigerant
liquid then passes through a filter drier and capillary tubing
which causes the refrigerant pressure and temperature to
drop. It next enters the evaporator coil where it absorbs
heat from the incoming air and evaporates. The evaporator
operates in a flooded condition, which means that all the
evaporator tubes contain liquid refrigerant during normal
operation. A flooded evaporator should maintain nearly
constant pressure and temperature across the entire coil,
from inlet to outlet.
CONDENSER
EVAPORATOR
CAPILLARY
TUBES
ACCUMULATOR
COMPRESSOR
STRAINER/FILTER
DRIER
M27404