STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances.
If unsure about household wiring procedures, call your
local heating/air-conditioning contractor.
Refer to the labels you placed on the wires when you removed
the old thermostat (see illustration).
Match the letter of old thermostat wire with the corresponding
terminal letter on new thermostat. Refer to Table 1.
Remove factory-installed jumper connecting terminals R and
RC if wires are connected to both of those terminals.
For wiring diagrams, if needed, see Wiring Diagrams section.
Loosen terminal screws. Slip each wire beneath matching
terminal. Wraparound and straight connections are both
acceptable, (see illustration). Tighten terminals.
Plug the hole in the wall with insulation to help prevent
drafts from adversely affecting thermostat operation.
M482
6
F
OR WRAPAROUND
I
NSERTION STRIP
7
/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
M16425
R
W
Y
G