Honeywell CT8602 Thermostat User Manual


 
15 69-1532—2
Table 2 shows the default temperature settings.
Table 2. Default Temperature Settings.
a
Your heating setpoints cannot be higher than 90°F (32°C) or lower than 40°F (4.5°C).
b
Your cooling setpoints cannot be higher than 99°F (37°C) or lower than 45°F (7°C).
Program the First Day
Start by programming the wake time and temperature for one day.
Press and release .
Press until the desired day displays (Mon, Tue, Wed, Thu, Fri, Sat, Sun).
Press time or until the desired time shows in the display.
NOTE: Program times are in 15 minute intervals. For example, 8:00, 8:15, 8:30.
Press or until the desired wake temperature displays.
The setpoint temperature range is 40°F to 90°F (4.5°C to 32°C) for heating and 45°F to 99°F (7°C to 37°C) for cooling.
Press to switch between setpoints.
NOTE: Program times are the same for heating and cooling.
Period Time Heating
a
Temperature Cooling
b
Temperature
Wake 6:00 AM 70°F/21°C 78°F/25.5°C
Leave 8:00 AM 62°F/16.5°C 85°F/29.5°C
Return 6:00 PM 70°F/21°C 78°F/25.5°C
Sleep 10:00 PM 62°F/16.5°C 82°F/28°C
Wake
Day
Heat/Cool
Settings