Honeywell CL60PM Fan User Manual


 
CLEANING
& MAINTENANCE
MAINTAING AND CHANGING THE HONEYCOMB
The appliance is supplied with Honeycomb cooling media.
Draining the water reservoir and refilling with fresh water at
least once a week will greatly reduce mineral deposits in the
pads and help to extend the life of Honeycomb cooling media.
Do not run the unit in COOL mode with stale water in the tank.
It is recommended to empty the tank and refill it with fresh
water if the water has been standing in the tank for an
extended period of time
The frequency for cleaning depends on local air and water
conditions. For example, in areas where mineral content of
the water is high, deposits may build up in the Honeycomb
cooling media, restricting air flow. In this case, i t i s
recommended to clean the Honeycomb cooling media every
two months.
For best results, allow the Honeycomb cooling media to dry
after each use by turning off the cool function 15 minutes
before turning the unit off.
11