Honeywell 9000 Home Security System User Manual


 
INTELLIGUARD 9000™ SECURITY SYSTEM
5 74-3035—2
For installation or service, three onboard switches—in
conjunction with the LED display—allow the technician to
configure the unit. In this mode, the BIC-6 annunciates the
programmed loop type for each loop which can then be
modified using the switches.
Features
Enclosure tamper switch.
Six independently programmable loops—four loop
types:
N.C. loop with EOLR.
N.O. loop with EOLR.
Output.
N.C. loop with no EOLR.
Interface is via three on-board push button
switches and the 7-segment display.
Serial numbered device, no address switch setting
required—learned using the programming interface in
conjunction with a CC2 Keypad or using PRO9000.
Status transmission (Alarm, Trouble, Tamper).
Model:
8003-238 Six Entry Concentrator (BIC-6) Module.
Electrical Ratings:
Nominal Operating Voltage: 12 Vdc to 15 Vdc.
Operating Voltage: 10 Vdc to 18 Vdc.
Minimum Operating Current: 16 mA at 14.5 Vdc (all loops
open).
Nominal Operating Current: 35 mA at 14.5 Vdc (all loops nor-
mal with a 2.2K ohm EOLR).
Maximum Operating Current (all input loops shorted, P0 = 1):
Normal Mode: 69 mA at 14.5 Vdc (type 2, 6 displayed).
Service Mode: 73 mA at 14.5 Vdc (type 4, 0 displayed).
Maximum Loop Distance: 250 ft (76m), 22 AWG (0.34 sq
mm), twisted pair cable. UL and ULC limit the distance to
50 ft (15m).
Typical Loop Output Drive Current:
Direct LED Drive: 5.5 mA (not included in operating cur-
rents above).
Relay or Other Device: 80 mA maximum at 14.5 Vdc or
Operating Voltage, whichever is less (not included in
operating currents above).
Typical of Loop Inputs:
Time to Trigger BIC-6 Input: 750 mS min.
Cleaning Current of Detector Contacts Connected to
Loops: 1 mA maximum.
Annunciation:
Display: 7-Segment LED.
Information:
Communication Status: Unit must be in tamper alarm.
All Loop Status: Unit must be in tamper alarm or the
respective parameter must be enabled.
Loop Type during Local Programming: Unit must be in
tamper alarm.
Communication: RS-485 receiving and transmitting signals.
Enclosure: Plastic polycarbonate base, ABS plastic cover.
Dimensions: 6-7/8 in. (174 mm) wide x 3-3/4 in. (94 mm)
high x 1-1/4 in. (30 mm) deep.
Weight: 0.62 lb (0.28 kg).
Approvals: UL, ULC, CE.
BIC-2 Input Concentrator
The BIC-2 supports a maximum of two
input (detection) and one output,
configured by the installer. The inputs
can be any standard detection device
such as a sensor or contact switch,
but must be normally open circuits. The output may be any
standard notification device such as a bell or light. The BIC-2
transmits information from the intrusion detection devices to
the CU.
Features
Enclosure tamper switch.
Serial numbered device, no address switch setting
required—learned using actuator buttons in
conjunction with a CC2 Keypad or using PRO9000.
Status transmission (Alarm, Trouble, Tamper).
Honeywell patented.
Models:
8003-242 BIC-2 Input Module with white actuator buttons. The
BIC-2 actuator buttons may be used as any push button
input to the system as required (except holdup). Push but-
ton activated by squeezing both white buttons at the same
time.
8003-284 BIC-2 HU Input Module with Hold-up Actuator. The
BIC-2 HU allows the user to send a distress signal to the
I9000 Control Unit by squeezing both red buttons at the
same time.
4545-059 Optional Relay for BIC-2. The optional relay for
BIC-2, or BIC-2 HU provides one normally open or nor-
mally closed dry contact.
NOTE: If using the relay option, loop 2 is not available on
either model.
Electrical Ratings:
Nominal Operating Voltage: 12 Vdc to 14.5 Vdc.
Operating Voltage: 10 Vdc to 15 Vdc.
Minimum Operating Current: 7.6 mA at 14.5 Vdc (both loops
normal, no optional relay, no output active, not polled or
idle).
Nominal Operating Current: 8 mA at 14.5 Vdc (both loops nor-
mal, 2.2K EOLR, no optional relay, no output active).
Maximum Operating Current: 31 mA at 14.5 Vdc (loop 1
shorted to ground, optional relay in closed position with
output active).
Maximum Loop Distance: 250 ft (76m), 22 AWG (0.34 sq
mm), twisted pair cable. UL and ULC limit the distance to
50 ft (15m).
Two loops jumper-programmable to a value of end-of-line
resistor (EOLR): 2.2K (as shipped) or 22K ohm. The
jumper affects both loops simultaneously.
Open Collector Output Switching Maximum: 20 mA at 14.5
Vdc or Operating Voltage, whichever is less.
One Optional Plug-in Relay Contact (normally open or nor-
mally closed): 30 Vdc at 1A.
Optional Relay Minimum Load Switching Current: 0.01 mA at
10 mV.
NOTE: If using the relay option, loop 2 is not available on
either model.
Annunciation: Red LED communication status indicator visi-
ble through one of the actuator buttons.