Honeywell 9000 Home Security System User Manual


 
INTELLIGUARD 9000™ SECURITY SYSTEM
74-3035—2 2
All events are sorted by day and date and then recorded in an
event log.
The I9000 recognizes a maximum of 99 users, plus one
reserved for service personnel, and five security levels with
individual identification numbers (ID) and passwords.
SPECIFICATIONS
Each component of the I9000 has the following temperature
and humidity requirements:
Temperature Ratings: 32°F to 120°F (0°C to 49°C).
Humidity Ratings: 5% to 95% at 86°F (30°C) RH, non-
condensing.
I9000 Control Unit
The Control Unit includes the
8003-295 Intelligent Switching
Power Supply (ISP) and the
8003-331 Intelligent
Communications Processor II
(ICP II). The I9000 Control Unit
supports up to 62 devices, 31
on each of two communication
ports, with 512 input points and
64 output points. The Control
Unit receives an intrusion
alarm signal from a BIC-6, BIC-2, or HEDS IV. The CU
processes the signal and sends it to the EBI, output devices,
or both. The EBI uses the signal to take the appropriate
action. The MOM, BIC-6 (configured for output), BIC-2,
BIC-2 HU, or ISP output activates any local alarms such as a
siren, light, or buzzer that are attached to the system.
The control unit supports up to eight ISPs, one of these is the
ISP contained in the I9000 Control Unit enclosure itself and
counts as one of the 62 devices. The other ISPs are located in
RIPs, one ISP per RIPS. Depending on the installation power
backup requirements, up to two batteries can be connected to
the ISP. When the ISP programmable output is used, two
batteries are recommended.
For added security, system configuration is only accessible
using the service technicians ID and Code with the control unit
in tamper alarm.
Model: 8003-332 I9000 EBI/Orbix Control Unit.
Firmware:
8950-109: Supports the I9000 EBI/Orbix protocol (included).
8950-100: Only supports existing XSM installations.
NOTE: Firmware 8950-100 (SMP protocol) must be ordered
separately and field swapped at installation time.
Electrical Ratings:
Transformer: Must be connected to a non-switched electrical
circuit.
Type: Class II Energy Limiting.
Output Voltage: 16 Vac.
Output Current: 2.3A.
Power Rating: 37 VA.
Intelligent Switching Power Supply (ISP)
ISP FEATURES
Red LED Communication Indicator is disabled if no
jumper is present on the ISP tamper input.
Green LED AC On Indicator.
Switch selectable address (0, 1, 2, or 3). Learned using
CC2 or PRO9000.
Switch selectable programmable output mode (steady
or pulsing).
Status transmission (Low Battery, AC Fail, Tamper).
RS-485 receiving and transmitting signals.
Electrical Ratings:
Operating Voltage: 13.6 Vac to 17.6 Vac.
ICP Power Consumption during AC failure: 20 mA at 13.8 Vdc
(maximum battery voltage). Add programmable output load
current to this value if the output is used.
Outputs: 2 x 400 mA maximum at 12.9 Vdc ± 4%. One pro-
grammable switched output at 1A, 12 Vdc.
NOTE: Power for the ISP programmable switched output is
partly obtained from the standby batteries. There-
fore, this output should be used to drive loads such
as sirens and bells for short durations (15 minutes
maximum). Otherwise the battery capacity will be
reduced and this will affect the total backup time
available for the devices connected to that ISP.
Standby Batteries:
Model: YUASA P/N NP7-12, or equivalent.
Electrical Ratings: 12V, 7 Ah.
Type: Sealed lead acid.
Quantity: Two, maximum.
Dimensions, maximum: 2-9/16 in. (65 mm) wide x 3-7/8 in.
(98 mm) high (including terminals), x 6 in. (152 mm) deep.
Weight: 6.17 lb (2.65 kg).
Intelligent Communications Processor II (ICP II)
ICP II FEATURES
Enclosure tamper switch input.
Two RS-485 ports for communicating with peripheral
devices (receiving and transmitting signals).
One RS-232 port for communicating with an EBI
station, or for remote programming from a PC via
PRO9000 (receiving and transmitting signals).
Red communication status LEDs for all three ports. To
save power, LEDs disabled when tamper normal.
On-board independent battery backup for Real Time
Clock and data memory. Ten year battery life.
Reports a loss of Real Time Clock operation to the EBI
(F/W 8950-109 only; must be programmed in I9000).
Reports a loss in device communication (must be
programmed in I9000).
Push button switch and yellow LED cold start
indicator.
Electrical Ratings:
Operating Voltage: 10 Vdc to 18 Vdc.
ICP II Power Consumption: 55.4 mA at 14.5 Vdc.