Honeywell 9000 Home Security System User Manual


 
INTELLIGUARD 9000™ SECURITY SYSTEM
74-3035—2 4
Control Center 2 Keypads
Each I9000 CU supports a
maximum of four Control
Center 2 (CC2) Keypads, two
per communication channel
maximum. Each CC2 displays
current system status and
allows local system control.
The operator can perform all
functions related to
programming, arming and
disarming any area at the CC2.
Features
Automatically learned by the I9000 CU at power up.
Can be programmed via DIP switch for no backlighting
or backlighting with auto shutoff after five minutes of
no activity.
Tone volume programmable via DIP switch for Low or
High output.
Supports four different addresses, programmable via
DIP switches.
Model: 8003-277 Control Center 2 Keypad.
Electrical Ratings:
Nominal Operating Voltage: 12 Vdc to 15 Vdc.
Operating Voltage: 10 Vdc to 18 Vdc.
Nominal Operating Current: 10 mA at 14.5 Vdc, no backlight-
ing, (107 mA with backlighting).
Annunciation: Two line by 24 character LDC display with
backlighting. Backlighting can be disabled to conserve
power. A red LED and a tone give the user visual and audi-
ble keystroke feedback.
Keypad: Membrane keypad with 20 keys.
Communication: RS-485 receiving and transmitting signals.
NOTE: Control Center 2 Keypads should be equally divided
among the two RS-485 communication lines to maxi-
mize system performance.
Enclosure: Plastic polycarbonate base, ABS plastic cover.
Dimensions: 6-7/8 in. (174 mm) wide x 3-3/4 in. (94 mm)
high x 1-1/4 in. (30 mm) deep.
Weight: 0.72 lb (0.33 kg).
Approvals: UL, ULC, CE.
Area Keypads
Each I9000 CU supports a
maximum of eight Area
Keypads. Each Area Keypad
(KID) shows the user if a
specific area is armed or
disarmed. The operator can
arm, disarm, force arm, or
partially arm a specific area at
the KID.
Features
Serial numbered device—no address switch setting
required—learned through the KID Keypad in
conjunction with a CC2 Keypad or using PRO9000.
Quick Reference guide (protruding from the top of the
KID) can be extended as required.
Keypad insert can be used to identify the four
programmable LEDs at installation.
Model: 8003-220 Area Keypad.
Electrical Ratings:
Nominal Operating Voltage: 12 Vdc to 15 Vdc.
Operating Voltage: 10 Vdc to 18 Vdc.
Nominal Operating Current: 28.6 mA at 14.5 Vdc.
Annunciation: Six LEDs; Arm/Disarm status (bi-color), ID/
Code status (tri-color) and four red LEDs (control unit pro-
grammable), provide system feedback.
Keypad: Membrane keypad with 12 keys.
Communication: RS-485 receiving and transmitting signals.
NOTE: Area Keypads should be equally divided among the
two RS-485 communication lines to maximize sys-
tem performance.
Enclosure: Plastic polycarbonate base, ABS plastic cover.
Dimensions: 6-7/8 in. (174 mm) wide x 4-3/16 in. (106 mm)
high x 1-1/4 in. (30 mm) deep.
Weight: 0.66 lb (0.30 kg).
Approvals: UL, ULC, CE.
BIC-6 Input Concentrator
Each I9000 CU supports a maximum
of 62 input devices. The BIC-6
supports a maximum of six detection
or output devices. The BIC-6 transmits
information from the intrusion
detection devices to the CU.
The BIC-6 is a combination input/output device. It has six
loops. Each loop can be configured for input or output,
independently from the other loops in the BIC-6. Each loop
can be configured for normally open or normally closed
contacts. Each loop can be wired with or without an end-of-
line resistor (EOLR) depending on the loop type chosen. A
loop configured as an open collector output may be used to
drive an external LED directly (no external resistor required), a
low current/voltage device or a relay module if a higher drive
or isolation is required.
The BIC-6 can annunciate alarm or trouble in any loop on a 7-
segment LED local display independently of the control unit,
provided the corresponding BIC-6 parameter has been
enabled. If several loops are abnormal, the local display
automatically scrolls and displays all abnormal loops.