Honeywell 69-2413ef-05 Dehumidifier User Manual


 
WIRING
Wiring Configuration: Advanced Models (HE150/HE250/HE300)
Wiring TrueEASE to equipment with powered terminals.
Wiring TrueEASE to equipment with powered terminals.
Wiring Configuration: Basic Models (HE100/HE200)
ADD 24VAC ISOLATION RELAY (SUCH AS R8222B1067) BETWEEN
THE HUMIDIFIER AND THE AIR HANDLER.
THE 50027910-001 AIR-FLOW SWITCH (AFS) IS RECOMMENDED
TO ENSURE AIR FLOW WHEN THE HUMIDIFIER IS RUNNING. IF
THE AFS IS USED, SET DIP SWITCH 1 TO OFF (LEFT).
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
WIRING DIAGRAM ASSUMES THE USE OF EQUIPMENT-SPECIFIC
COMMUNICATING THERMOSTAT CONTROLLING THE HUMIDIFIER.