Honeywell 69-2413ef-05 Dehumidifier User Manual


 
PLUMBING
Water Supply and Drain Connections
STEP ONE: Connect the Water Supply
Use hot or cold water.
Cut the water line so it reaches from the humidifier to
the main water supply tap
Insert the water line into the gray quick connect
fitting. Insert it fully, and apply modest pull pressure to
ensure a tight fit.
Note: The quick connect fitting can be removed if you
prefer to use a standard 1/4-in. brass compression
nut plumbing connection. Do not remove the conical
screen if you select this option.
STEP TWO: Tap into a Water Line
• Consult local codes for proper plumbing.
• Use the saddle valve provided or a T-fitting and
manual shutoff valve to tap into the water line.
• Refer to the literature included with the valve you
chose and the local plumbing codes. Use proper
technique for the valve.
• Connect the other end of the humidifier water line
to the water valve.
MCR32931
Saddle Valve
T-fitting
Water Supply
Line
Manual Shutoff
Valve
M29605
2
1
Humidifier 69-2413EF—05
13