Honeywell 69-2092EFS-07 Thermostat User Manual


 
FocusPRO
®
Thermostat Installation Guide
69-2092EFS—07 6
36 Zone name 52 Thermostat
1 Basement 16ExerciseRoom 30Library 44Porch
2 Bathroom 17 Family Room 31LivingRoom 45RecRoom
3 Bathroom 1 18 Fireplace 32LowerLevel 46SewingRoom
4Bathroom2 19 Foyer 33 Master Bath 47Spa
5Bathroom3 20 Game Room 34MasterBed 48StorageRoom
6Bedroom 21 Garage 35MediaRoom 49Studio
7 Bedroom 1 22 Great Room 36MusicRoom 50SunRoom
8 Bedroom 2 23 Guest Room 37 Nursery 51Theater
9 Bedroom 3 24Gym 38 Office 52Thermostat
10Bedroom4 25Kid'sRoom 39 Office 1 53UpperLevel
11 Boat House 26Kitchen 40Office2 54UtilityRoom
12 Bonus Room 27Kitchen1 41Pantry 55WalkInCloset
13 Computer Room 28Kitchen2 42PlayRoom 56WineCellar
14Den 29LaundryRoom 43PoolRoom 57Workshop
15DiningRoom
39 Wireless setup 0 Disconnect thermostat from wireless system
1 Thermostat is connected to wireless system
90 RESET 0 No reset
1 Reset installer options & program schedule to factory default
settings
Installer setup tables
Setup function Settings & options (factory default in bold)
Special functions
Heat Pump Control — Fossil Fuel Backup (Setup Function 18):
Note: If temperature is not reached in a reasonable time, set the upstage to furnace timer
(function 21). After the designated time, the compressor will turn off and the system will switch
to back up heat.
Heat Pump Control — Electric Backup (Setup Functions 24-25):
40
55
M28705
COMPRESSOR LOCKOUT
AUXILIARY LOCKOUT
COMPRESSOR AND FAN ONLY
COMPRESSOR AND FAN OPERATE
ELECTRIC BACKUP HEAT AND FAN ONLY
OUTDOOR TEMP.
IF THE COMPRESSOR CANNOT REACH OR MAINTAIN TEMPERATURE SETTING,
BOTH THE COMPRESSOR AND ELECTRIC BACKUP HEAT WILL OPERATE.
1
1
M28706
IF ROOM TEMPERATURE DROPS (EXCEEDS DROOP SETTING AT FUNCTION 20), COMPRESSOR IS DEACTIVATED. FOSSIL FUEL
BACKUP HEAT IS ACTIVATED AFTER 3 MINUTE DELAY.
1
FOR GEOTHERMAL HEAT PUMPS, THE BALANCE POINT CAN BE DISABLED AT SETUP FUNCTION 24.
**
OPTION 0: NO DROOP CONTROL
40
BALANCE
POINT **
COMPRESSOR AND
FAN ONLY
FOSSIL FUEL
BACKUP HEAT ONLY
OUTDOOR TEMP.
OPTION 1: DROOP CONTROL
OUTDOOR TEMP.
40
BALANCE
POINT **
COMPRESSOR AND
FAN OPERATE
FOSSIL FUEL
BACKUP HEAT ONLY
1
OPTION 2: DROOP CONTROL WITH AUX HEAT LOCKOUT
COMPRESSOR AND FAN OPERATE
OUTDOOR TEMP.
40
55
BALANCE
POINT **
AUXILIARY
LOCKOUT
COMPRESSOR AND FAN ONLY
FOSSIL FUEL BACKUP HEAT ONLY
1
Comfort/Economy Setup Function 26 (Not available when Setup Function 17 is set to 0):
If you choose Comfort, auxiliary heat will respond quickly to meet the temperature
setpoint. If you choose Economy, the system will wait longer. Auxiliary heat will be
activated only if the setpoint is not reached within a reasonable time.