Honeywell 69-2092EFS-07 Thermostat User Manual


 
FocusPRO
®
Thermostat Installation Guide
69-2092EFS—07 4
Installer setup tables
Setup function Settings & options (factory default in bold)
0 Zone number 0 Nozoning(singlethermostatusedwithTHM5320REIM)
[Options:selectzone1,2,3or4]
1 System type 0 1 heat/1 cool conventional
1 1 heat/1 cool heat pump (no aux. heat)
2 Heat only (includes Series 20)
3 Heat only with fan
4 Coolonly
5 2heat/1coolheatpump
6 2heat/2coolconventional
7 2 heat/1 cool conventional
8 1 heat/2 cool conventional
9 2 heat/2 cool heat pump
10 3 heat/2 cool heat pump
2 Changeover valve
(O/B terminal)
0 O/B terminal controls valve in cooling
1 O/B terminal controls valve in heating
3 Fan control
(conventional heat)
0 Gas/Oil heat (equipment controls fan)
1 Electric furnace (thermostat controls fan)
4 Backup heat
(EIM only)
1 Electric backup heat
0 Fossil fuel backup heat
5 Stage 1 heat cycle
rate (CPH: cycles per
hour)
5 Gas or oil furnaces (less than 90% efficiency)
1 Steam or gravity systems
3 Hot water systems & furnaces of over 90% efficiency
9 Electric furnaces
[Cyclerateoptions:1to12CPH]
6 Stage 2 heat cycle
rate (CPH)
5 Gas or oil furnaces (less than 90% efficiency)
1 Steam or gravity systems
3 Hot water systems & furnaces of over 90% efficiency
9 Electric furnaces
[Cyclerateoptions:1to12CPH]
7 Stage 3 heat cycle
rate (CPH)
5 Gas or oil furnaces (less than 90% efficiency)
1 Steam or gravity systems
3 Hot water systems & furnaces of over 90% efficiency
9 Electric furnaces
[Cyclerateoptions:1to12CPH]
8 Emergency heat cycle
rate (CPH)
9 Electric furnace
[Cyclerateoptions:1to12CPH]
9 Stage 1 compressor
cycle rate
3 Recommended cycle rate
[Cyclerateoptions:1to6CPH]
10 Stage 2 compressor
cycle rate
3 Recommended cycle rate
[Cyclerateoptions:1to6CPH]
11 Heat pump type
(EIM only)
0 Air to Air Heat Pump
1 Geothermal heat pump
12 Manual/Auto
changeover
0 Manual (User options: Heat/Cool/Off)
1 Automatic (User options: Heat/Cool/Auto/Off)
13 Adaptive Intelligent
Recovery
AppliesonlytoModelTH6320
0 Off
1 On
14 Temperature
display
0 Fahrenheit
1 Celsius
15 Compressor off time 5 5 minutes (Heat On/Cool On flashes during off time)
[Options:0to4minutes]
16 Schedule format
AppliesonlytoModelTH6320
0 Weekday/weekend program schedule
1 Weekday/Saturday/Sunday program schedule