Brine Valve Settings
Unit Brine Setting
Float Cup
Height
WS-C206 .5 lb. 5.25"
WS-C206 1.0 lb. 6.25"
WS-C208 1.0 lb 5.25"
WS-C208 1.4 lb 5.75"
23. After the adjustments have been made to the
float cup, reinstall brine valve into the cabinet.
NOTE: Do not drop brine valve into drum. Dropping
may lower float cup, resulting in an improper setting.
24. Add a clean grade of salt at this time. Higher
grades of Pelletized Salt for impurities and
solubility should be used.
NOTE: Do not use rock salt or solar salt.
25. Open inlet valve slowly allowing system to
pressurize.
26. Water and air will be expelled from drain until
system is completely pressurized.
27. A manual regeneration should be started to
purge air and color from softening system. This
is done by pushing down on actuator with a
Phillips screwdriver and rotating clockwise slowly
until pressure is felt.
28. Continue slowly until internal water flow is heard
at softener valve. The softener will automatically
run through a regeneration. This process should
be repeated in 12 to 15 minutes to flush other
resin tank.
29. Check for plumbing leaks.
30. Check unit for proper operation.
WS-C206/WS-C208 Hobart Compact Water Softener Installation Instructions - INSTALLATION