Hobart WS-C206 Water System User Manual


 
14. Insert tubing provided into the overflow port on
the back of the softener and run drain lower than
the cabinet connection to provide a gravity drain
in the event of a internal cabinet leak.
Fig. 10
15. Review the meter disc selection chart and the
water analysis provided. If no water analysis is
provided test the water supply.
16. To test the water supply, use the water analysis
test kit available through Pro Products Inc. The
recommended kit is #2401 Field Analysis Kit. To
order the test kit contact Pro Products at 800-
285-9176 or visit www.ProProducts.com.
17. Determine the correct number disc. DISC
SELECTION WS-C206/WS-C208
NOTE: Both the WS-C206 and the WS-C208 have a
#4 meter disc installed at the factory. If this is not the
correct disc for a given application, locate the meter
disc kit and follow instructions for DISC
REPLACEMENT WS-C206/WS-C208
18. Remove brine valve assembly from cabinet to set
float cup.
19. To remove brine valve assembly, disconnect
tubing from valve elbow by holding the collet and
pulling tubing straight away. Remove brine valve
from softener cabinet.
Fig. 11
20. Remove the brine valve assembly by lifting
straight up.
21. Set it on a flat surface, to measure height of float
cup.
22. Measure from bottom of brine valve to top of float
cup.
Fig. 12
WS-C206/WS-C208 Hobart Compact Water Softener Installation Instructions - INSTALLATION
Page 5 of 10 F25311 Rev. A (0913)