Heatiator C40 Indoor Fireplace User Manual


 
4/20/11
Heatilator Constitution EPA Fireplace 480-1091D
Page 57
Non-Combustible Sealant Material

After completing the framing and applying the facing mate-
rial (drywall) over the framing, a bead of non-combustible
sealant must be used to close off any gaps at the top and
sides between the replace and facing to prevent cold air
leaks. Large gaps can be bridged with berglass rope gas-
ket.
Only non-combustible materials may be used to cover the
metal replace front.
Cardboard OR Metal Template
A cardboard template of the front is printed on the outside of
the shipping box. It measures 1/8 in. (3 mm) bigger all the
way around than the actual front. Cut out the template
along the outside of the line for use in your installation.
A metal template is also available for more durable
continued
use remaining accurate over time. See page 64 for catalog
number.
Warning Fire Risk!
Maintain clearances
-





60 in.
(1524mm)
Mantel
Clearances are
from bottom of
appliance to lower
edge of mantel or
trim
Trim
48 in.
(1219mm)
A combustible mantel may be positioned no lower than 60 in.
(1524mm) from the base of the replace.
The combustible mantel may have a maximum depth of 12 in.
(305mm). Combustible trim pieces that project no more than
3/4 in. (19mm) from the face of the replace can be placed
no closer than 6 in. (152mm) from the side of the decorative
front. See Figure 10.9
Combustible trim must not cover:
the metal surfaces of the replace
where the non-combustible board is placed over the metal
surfaces
the space between the metal face of the replace and framing
members.
Figure 10.9 Mantel Specications
WARNING! Fire Risk
-
-

 
F. Mantel
Refer to page 37 for clearance requirements