Heath Zenith Motion Sensing Coach Lights Home Safety Product User Manual


 
2
598-1207-01
INSTALLATION
For best performance, mount the fixture about
6 feet (1.8 m) above the ground.
ON-TIME Switch at 1,
5, or 10 minutes
Mode Switching Summary
Flip light
switch off for
one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes,
turn the power off for one minute, then back
on. After the calibration time the control will
be in the AUTO mode.
DualBrite
®
Dimmer Control
Light comes on half bright for selected time af-
ter dusk (Off, 3 hr., 6 hr., until dawn). Selecting
OFF disables this feature. The motion sensing
features will continue to work as described
in this manual. If motion is sensed, the light
turns on full bright for the ON-TIME (1, 5, or
10 minutes) then returns to dim mode.
WARNING: Turn power off at circuit
breaker or fuse.
This fixture comes with a universal mounting
bracket. It is pre-assembled on the fixture to
fit the majority of junction box applications.
However, if the slots on the mounting plate
do not line up with the junction box screw
holes:
1. Remove the fixture mounting screws from
the mounting plate. Note: Do not remove
the ground screw.
2. Attach ground wire “pigtail” to ground
screw on mounting plate (See Recom-
mended Grounding Method for additional
information).
3. Flip the mounting plate over.
MAX
SENS
MIN
4. Set sensitivity control on back
of fixture to mid-position.
1. Remove two nuts.
5. Attach mounting
plate to junction box.
Wire Path
Ground Screw
3. Tighten screws
finger tight.
2. Remove