8 598-1347-00
Junction box ground wire to green
ground screw on xture.
Wiring Floodlight
WARNING: Risk of re. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
White to
White
Black to
Black
Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
PAR FLOODLIGHT
Features and Ratings:
• Up to 150 Watt maximum
incandescent load or 240 Watt
maximum halogen load (up to
75 Watt maximum incandescent,
or 120 Watt maximum halogen, per lampholder).
• Minimal wiring required.
• Install xture in accordance with local codes.
10. Screw incandescent bulb up to rated wattage into module.
When screwing in the lamps, do not overtighten.
WARNING: Turn power off at the fuse or circuit
breaker.
CAUTION: Do not exceed the maximum load limits
listed above.
CAUTION: To avoid water damage and electrical shock,
keep lamp holders 30° below horizontal.
1. Remove the existing light xture.
2. Install the mounting strap as shown using two screws that t
your junction box.
Note: The plastic hanger can be used to hold the xture while
wiring. Thread the small end of the plastic hanger through the
hole in the center of the cover plate. Insert the small end into
one of the slots on the mounting strap.
3. Set the LAMP MODE switch to the desired light turn-on effect
(Normal, Soft, Flash).
4. Route the wires from the light receiver through the large gasket
holes.
5. Twist the junction box wires and xture wires together as shown.
Secure with UL approved wire connectors.
6. Align the cover plate and cover plate gasket. Secure with
mounting bolt.
7. Push the rubber plug rmly into place.
8. Not intended for waterproof junction boxes. Fixture should be
surface mount only. Caulk the wall plate mounting surface with
silicone weather sealant.
9. Adjust the lamp holders by loosening the lock nuts. Note: Do not
rotate the lamp holders more than 180° from the factory setting.
11. Check operation. Activate transmitter being used with receiver
(see transmitter instructions). A signal will be sent to the receiver
to turn the receiver ON or OFF.