Heat & Glo LifeStyle SL-750TV-D Indoor Fireplace User Manual


 
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/0710
C. Clearances
Figure 3.2 Clearances to Combustibles
C
B
D
A
Fire Risk.
Construct chase to all clearance speci cations
in manual.
Locate and install appliance to all clearance
speci cations in manual
Fire Risk.
Odor Risk.
Install appliance on hard metal or wood surfaces
extending full width and depth of appliance.
Do NOT install appliance directly on carpeting, vinyl, tile
or any combustible material other than wood.
Do NOT place furniture or any other combustible household
objects within 36 inches of the appliance front.
B. Constructing the Appliance Chase
A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that run
on the outside of a building may be, but are not required
to be, installed inside a chase.
Construction of the chase may vary with the type of building.
These instructions are not substitutes for the requirements
of local building codes. Local building codes MUST be
checked.
Chases should be constructed in the manner of all outside
walls of the home to prevent cold air drafting problems.
The chase should not break the outside building envelope
in any manner.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air in ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air in ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
To further prevent drafts in cold climates, the restops
should be caulked with high temperature caulk to seal gaps.
Gas line holes and other openings should be caulked with
high temp caulk or stuffed with unfaced insulation. If the
appliance is being installed on a cement slab, a layer of
plywood may be placed underneath to prevent conducting
cold up into the room.
G
I
H
E
F
J
Models A B C D E F G H I J
SL-550TV-D
Inches 10 33 16-1/4 37 31 0 0 1/2 1/2 36
mm 254 838 413 940 787 0 0 13 13 914
SL-750TV-D
Inches 10 38-1/4 16-1/4 42 31 0 0 1/2 1/2 36
mm 254 971 413 1067 787 0 0 13 13 914
SL-950TV-D
Inches 10 42-1/4 16-1/4 49 31 0 0 1/2 1/2 36
mm 254 1073 413 1245 787 0 0 13 13 914
WARNING
WARNING
Î