Fire Risk
Explosion Risk
• Facing and/or finishing materials must
never overhang into the glass opening.
Overhanging materials may ignite.
May interfere with proper operation of glass assembly.
Figure 11.3 Noncombustible Facing Diagram
A. Mantel Projections
Figure 11.1 shows the minimum vertical and correspond-
ing maximum horizontal dimensions of appliance mantels
or other combustible projections above the top front edge
of the appliance.
11
11
Finishing
Figure 11.1 Clearances to mantels or other combustibles
above appliance
Figure 11.2 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
B. Facing Material
WARNING
Fire Risk.
Finish all edges and fronts to clearances and
speci cations listed in manual.
Black metal appliance front may be covered with non-
combustible material only.
Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials only up to specified
clearances on top, front and side.
Seal joints between the nished wall and appliance top
and sides using only a 300º F minimum sealant.
WARNING
1/2 INCH
(13 mm)
32 IN.
(813 mm)
TOP OF HOOD
12 IN.
(305 mm)
NON-COMBUSTIBLE
MATERIAL ONLY
13 IN.
(330 mm)
CEILING
TOP FRONT EDGE OF FIREPLACE
Note: Clearance from opening
to perpendicular wall.
1 in.
MIN.
3 in.
MIN.
3 ft.
MAX.
TOP VIEW
Risk of Fire
• Non-combustible clearances MUST be
maintained.
Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-
combustible de nitions.
WARNING
NON-COMBUSTIBLE ZONE
MATERIAL SUPPLIED WITH UNIT
0 in. 0 in.
0 in.
2 in.
HIGH TEMPERATURE
(300º F /149º C. MIN.)
SEAL JOINT
FINISH WALL MATERIAL
MAY BE COMBUSTIBLE
- TOP AND SIDES -