Heat & Glo LifeStyle 6000G-IPI Air Conditioner User Manual


 
Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/0826
Figure 7.6 Remove the insulation from the outer vent
pipe. For rear venting there is no insulation in the outer
vent pipe.
Figure 7.7 To attach the rst section of vent pipe, make
sure to use the berglass gasket in the manual bag to seal
between the rst vent component and the outer replace
wrap. Use 2 self tapping screws to secure the gasket to
the outer wrap.
Secure the rst section of venting to the replace by screw-
ing through the two straps left over from cutting the seal
cap strap in step 2.
Figure 7.8 Non-combustible Board
B. Installing the Non-combustible Board
The factory supplied non-combustible board spans the
distance from the top of the replace to the center of
the framing header. This board must be used. See
figure 7.8.
HEADER
HEADER
C. Securing and Leveling the Appliance
The diagram shows how to properly position, level, and
secure the appliance (see Figure 7.9). Nailing tabs are pro-
vided to secure the appliance to the framing members.
Venting - refer to Vent Clearances and Framing (Section
6) for hole location.
• Place the appliance into position.
• Level the appliance from side to side and front to back.
Shim the appliance as necessary. It is acceptable to use
wood shims.
• Bend out nailing tabs on each side.
• Keep nailing tabs ush with the framing.
• Secure the appliance to the framing by using nails or
screws through the nailing tabs.
Figure 7.11 Proper positioning, leveling and securing of an
appliance
NAILING TABS
(BOTH SIDES)
Fire Risk.
ALWAYS maintain speci ed
clearances around the appliance.
Do NOT notch into the framing around the appliance spacers.
Failure to keep insulation, framing or other material away from
the appliance may cause re.
Note: Once appliance is setup for top or rear venting, it
CANNOT be changed at a later time.
Fire Risk.
Prevent contact with sagging, loose insulation.
Do NOT install against combustible materials
such as exposed insulation, plastic and insulation
backer.
WARNING
WARNING
Note: Once appliance is setup for top or rear venting, it