Heat Controller VMH 36 Heat Pump User Manual


 
5
Heat Controller, Inc. VMH 30/36 SERIES Installation, Operation & Maintenance
1. For the left-hand and right-hand piping,
remove the pipe cover from the side panel.
2. For the rear-right-hand and rear-left-hand
piping, install the piping as shown.
3. Bundle the tubing, connecting cable, and
drain hose with tape securely, evenly as
shown in Figure on the right.
Because the condensed water from rear
of the indoor unit drains to the ponding
box before drainage through the drain
hose, be sure not to place anything inside
the ponding box.
1. Run the drain hose sloping downward.
The figures on the right show improper
installation methods.
2. When conne
cting extension drain hose,
insulate the connections, do not let
the drain hose slack.
Connect the indoor unit first, then the
outdoor unit.
Do not allow the piping to come out from the
back of the indoor unit.
Be careful not to let the drain hose slack.
Heat insulate both the auxiliary piping.
Be sure that the drain hose is located at
the lowest side of the bundle. Locating at
the upper side can cause drain pan to
overflow inside the unit.
Never intertwine the condensate piping the power
wire with any other wiring.
Run the drain hose slopped downward to
drain out the condensed water freel
y.
the power
1. Pass the piping through the hole in the wall.
2. Hook the indoor unit onto the upper portion
of installation plate(Engage the indoor unit with
the upper edge of the installation plate). Ensure
the slots are properly seated on the installation
plate hooks by moving it in left and left.
3. Piping installation can easily be done by placing
a temporary piece of styrofoam between the
unit and the wall. After piping is complete, be
sure to remove the styrofoam.
4. Press the lower left and right side of the unit
against the installation plate until the slots
hook onto and engage wi
th the installation
wall plate.
CONNECTIVE PIPE AND DRAINAGE INSTALLATION
3
Connective pipe installation
Drainage
CAUTION
Indoor unit installation
Insulation
INDOOR SECTION