Heat Controller REG-123A Air Conditioner User Manual


 
Service Manual 19
Disassembly
13. Motor
1. Remove the cabinet. (Refer to section 2)
2. Remove the evaporator. (Refer to section 4)
3. Remove the orifice. (Refer to section 4)
4. Remove the blower. (Refer to section 4)
5. Remove the fan. (Refer to section 5)
6. Remove the control box cover and disconnect 5
or 4 wires of motor housing. (Refer to section 3)
7. Remove the 2 or 4 screws that fasten the motor
from the mount motor. (See Figure 28)
8. Remove the motor.
9. Re-install the components by referring to the
removal procedure, above.(See Figure 28)
CAUTION: Discharge the refrigerant
system using a Freon
TM
Recovery
System. If there is no valve to attach the
recovery system, install one (such as a
WATCO A-1) before venting the Freon
TM
.
Leave the valve in place after servicing
the system.
14. Condenser
1. Remove the cabinet. (Refer to section 2)
2. Remove the 4 screws that fasten the
brace.(Refer to section 4)
3. Remove the 5 screws that fasten the condenser
and shroud.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the con-
denser connections.
5. Remove the condenser.
6. Re-install the component by referring to notes.
(See Figure 29)
15. Evaporator
1. Remove the cabinet. (Refer to section 2)
2. Remove the 2 screws that fasten the
evaporator.
3. Move the evaporator sideways carefully.
(Refer to section 4)
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evapo-
rator connections.
5. Remove the evaporator.
6. Re-install the component by referring to notes.
(See Figure 30)
Figure 28
Figure 29
Figure 30
Refrigerating Cycle