Heat Controller HTD SERIES Heat Pump User Manual


 
Heat Controller, Inc. HTV/HTD/HTH SERIES Engineering Design Guide
10
Heat Controller GeoMax 2
n
Geothermal Heat Pump Systems
Dimensions – Vertical Downow
ClimateMaster Geothermal Heat Pump Systems
TT
27
All Products Technical Guide: 2008 - 2009
Dimensions — Vertical Downflow Tranquility
27™
2’ [61cm] Service
Access
Air Coil Side
K
J
L
4
3
2
1
5
CAP
T
U
R
S
Air Coil
CSP
Front
Back
Front-View
BSP
Left Return Left View
- Filter Rack Knife Edge
Condensate
3 / 4” Glue
(Left Return)
Condensate
3 / 4” Glue (Right Return)
5
1.1 [27.9mm]
1.6 [40.6mm]
T
U
S
Air Coil
Front
Back
Right Return Right View
- Filter Rack Knife Edge
R
ASP
Legend
CAP=Control Access Panel
CSP=Compressor Service Panel
BSP=Blower Service Panel
ASP=Alternate Service Panel
Front
P
O
N
M
Blower
Opening
H
C
B
A
Front
P
O
N
Q
Blower
Opening
B
A
Right Return Discharge
Floor Foot Print
Left Return Discharge
Floor Foot Print
CSP
Isometric View
Condensate 3/4”
Glue
ASP
CSP
CAP
BSP
Deluxe Filter Bracket
2’ [61cm] Optional Service
Access Right Rtn
(left opposite)
ASP
E
Rev.: 7/26/04D
Air Coil Side
1.6 [40.6mm]
D
F
G
Power Supply
3 / 4” [19.1mm]
HV Knockout
1 / 2” [12.7mm]
Knockout
Low Voltage
1 / 2” [12.7mm]
LV Knockout
Vertical
Downflow
Model
Discharge Connection
Duct Flange Installed (+/- 0.10 in, +/- 2.5mm)
Return Connection
Standard Deluxe Filter Rack
(+/- 0.10 in, +/- 2.5mm)
M
Left
Return
N
O
Supply
Width
P
Supply
Depth
Q
Right
Return
R
S
Return
Depth
T
Return
Height
U
026
in
cm
6.7
17.1
8.4
21.4
9.9
25.3
9.1
23.0
10.8
27.4
1.7
4.2
22.2
56.4
26.2
66.4
21.2
53.9
038
in
cm
7.4
18.7
9.0
22.9
13.1
33.3
12.9
32.7
10.4
26.5
1.7
4.2
27.1
68.9
26.1
66.4
23.2
59.0
049
in
cm
7.4
18.7
9.0
22.9
13.1
33.3
12.9
32.7
10.4
26.5
1.7
4.2
27.1
68.9
30.1
76.5
23.2
59.0
064
in
cm
7.4
18.7
9.0
22.9
13.1
33.3
12.9
32.7
10.4
26.5
1.7
4.2
27.1
68.9
34.1
86.7
23.2
59.0
072
in
cm
7.4
18.7
9.0
22.9
13.1
33.3
12.9
32.7
10.4
26.5
1.7
4.2
27.1
68.9
34.1
86.7
23.2
59.0
070
060
048
036
024
Access Panels
Aux Htr Knock-Out
Power Supply
Low Voltage
External Pump
Access Panels
Filter Rack Dimensions
B
3Õ Service
Note:Filter Rack extends
out from cabinet 2.75Ó
C
1/2Ó LV
Knockout
3/4Ó HV
Knockout
G
F
3
1
2
1.6
E
D
4
H
5
O
P
NM
1.6
1.1
L
K
J
R
S
T
U
1/2Ó LV
Knockout
3/4Ó HV
Knockout
P
O
Q
N
Condensate 3/4Ó
glue socket
A
Left Return
Right Return
Discharge Dimensions
Discharge Dimensions
6.1
15.4
7.4
18.3
7.4
18.3
7.4
18.3
7.4
18.3
8.2
20.8
8.6
22.1
8.6
22.1
8.6
22.1
8.6
22.1
13.6
34.4
13.6
34.4
13.6
34.4
13.6
34.4
10.4
26.4
9.4
23.5
13.3
33.7
13.3
33.7
13.3
33.7
13.3
33.7
10.5
27.5
10.5
27.5
10.5
27.5
10.5
27.5
10.9
27.9
1.8
4.6
1.5
3.8
1.5
3.8
1.5
3.8
1.5
3.8
27.8
70.6
27.8
70.6
27.8
70.6
27.8
70.6
22.3
56.6
26.2
66.5
26.2
66.5
30.2
76.7
26.2
66.5
34.2
86.9
23.1
58.4
23.1
58.4
23.1
58.4
23.1
58.4
21.1
53.6
9
2”
Two Stage Geothermal Heat Pump Systems