Heat Controller HMH30BS-1SINGLE-ZONE Heat Pump User Manual


 
9
Insert the connecting cable into the indoor unit.
Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy
connection later.
Tape the drain hose and the connecting cable.
Connecting cable
C
D
Installation
plate
Three upper
hooks
Installation plate
Indoor unit
Three lower
hooks
Setting line
Connecting the pipings to the indoor unit and
the drain hose to drain pipe.
Put a couple drops of refrigerant oil on the face of
the flare before assembling taking care not to add
any contaminants
Align the center of the pipings and sufficiently
tighten the flare nut by hand.
Tighten the flare nut with a wrench.
F
Indoor unit tubing Flare nut Pipings
Torque wrench
Indoor unit tubing
Spanner (fixed)
Connection pipe
Flare nut
30k 5/8"[6.6kg
.
m] 3/8"[4.2kg
.
m]
Pipe Size[Torque]
Capacity
(Btu/h)
Suction Evaporator
E
Indoor unit installation
Hook the indoor unit onto the upper portion of
the installation plate.(Engage the three hooks
of the rear top and rear lower of the indoor
unit with the upper edge and lower edge of
the installation plate.) Ensure that the hooks
are properly seated on the installation plate by
moving it left and right.
Wrap the insulation material around the
connecting portion.
Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.
G
Plastic bands
Insulation material
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Indoor
unit piping
Pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
When extending the drain hose at the indoor unit,
install the drain pipe.
Wrap the area which accommodates the rear