Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traf c and away from furniture and draperies.
NOTICE: Illustrations re ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
A
B
C
D
E
F
B
F
B
E
D
A
Note: Dimensions below refer to a framed wall on
which 1/2 inch wall sheathing has not been installed.
ABC DEF
TRUE-36
Inches 74-1/4 59-1/2 105 26-1/2 23-1/2 29-3/4
Millimeters 1886 1511 2667 673 597 756
TRUE-42
Inches 78-9/16 65-9/16 111-1/16 28-5/8 23-1/2 32-13/16
Millimeters 1995 1665 2821 727 597 33
TRUE-50
Inches 84-1/4 73-9/16 119-1/8 31-1/2 23-1/2 36-13/16
Millimeters 2140 1868 3026 800 597 935