F. Sidewalls/Surrounds
Adjacent combustible sidewalls must be located
a minimum of 12 in. (305 mm) from the fireplace
opening.
Combustible or non-combustible mantel legs, surrounds
and stub walls may be constructed per Figure 11.12.
42 1/8 in.
[1070 mm]
36 in.
[914 mm]
12 in.
[305 mm]
14 1/2 in.
[368 mm]
12 in.
[305 mm]
10 3/4 in.
[273 mm]
FLUSH
FRONT
4 in.
[102 mm]
BRICK
FRONT
50° angle
39° angle
Figure 11.12 Mantel Leg or Wall Projections (acceptable on both
sides of opening)
G. Firebrick Installation
• The bottom rebrick is preinstalled.
Remove side brick pieces from inside of replace.
Set bottom of side brick (three bricks per side) into lower
brick support. See Figure 7.13.
Lift up outer edge of upper brick support just enough to
pivot brick under channel.
Push upper brick support down over bricks to hold the
bricks in place.
Repeat procedure for other side.
Upper Brick
Support
Lower Brick
Support
Channel
Figure 11.13 Side Brick Installation
Bend down
Figure 11.14 Brick Support Bracket
#ENTER
"RICK
"RICK
3UPPORT
"RACKET
'AS
,INE
Figure 11.15 Gas Line Installation
Heatilator • SC60 • 32838 Rev X • 10/08