Hearth and Home Technologies QV32EV, QV32E Indoor Fireplace User Manual


 
Hearth & Home Technologies - Colville
1445 North Highway, Colville, WA 99114-2124
VILLAGE COLLECTION ELECTRIC FIREPLACE
17
09/03
4030-240 Rev F
4. Heater System Maintenance
a. Turn off the circuit breaker/unplug the appliance before servicing the heater system.
b. Allow appliance to cool before removing.
c. Remove the hood by pulling it straight out.
d. Remove the upper panel/door front by lifting it up and out.
e. Remove the four outer screws. See Figure 20.
f. Pull the heater system out of appliance. With the heater system out of the appliance, reach into the back of the appliance and
unplug wire harness from connector. To remove plug squeeze both sides and pull.
g. Slide the heater system back into the appliance, making sure that the wires do not touch the heater housing. If the heater
system is not locked on the clip the front will not be flush.
h. Once the front of the heater system is flush with appliance, reinstall the four screws removed earlier.
i. Replace the upper panel and hood.
j. Turn on circuit breaker when heater installation is complete.
k. Follow the operating instructions found in section I. Operating Instructions.
2019
Installing the Heater
CAUTION:
Although the glass is safety glass, it may break if dropped, bumped
or struck. Care must be taken when handling the glass.