Hearth and Home Technologies QV32E (120V) Indoor Fireplace User Manual


 
Hearth & Home Technologies - Colville
1445 North Highway, Colville, WA 99114-2124
VILLAGE COLLECTION ELECTRIC FIREPLACE
9
09/03
4030-240 Rev F
G. FINISHING
Combustible Finishing Material
Materials made of or surfaced with wood, compressed paper, plant
fibers, plastics or any material capable of igniting and burning,
whether flame proofed or not, plastered or unplastered (this includes
drywall).
Noncombustible Finishing Material
Materials which will not ignite and burn. Such materials are those
consisting entirely of steel, iron, brick, tile, concrete, slate, glass or
plasters or combinations thereof, or have a UL Fire rating of Zero(0).
Note: The remote wall switch (hard wired appliances
only) must be wired prior to applying the finishing material
in order to avoid reconstruction.
Figure 5 - Finishing Materials
WARNING!
Grilles on this appliance cannot, in any way, be cov-
ered as it may create a fire hazard.
Finishing Checklist
1. Power supply service must be either completed or placed within the appliance prior to finishing to avoid reconstruction. Wall
switch wires (hardwired appliances only) must also be completed to avoid reconstruction. See Section F. Wiring.
2. Combustible material may cover the black outer surface by ½ on the 110/120v appliances only. See Figures 5-6.
Combustible material may not cover the black outer surface on 208/220/240V appliances. See Figure 7.
Grilles and air openings cannot be covered in any circumstances.
3. Noncombustible material may cover all black outer surfaces. Grilles and air openings may not be covered.
4. Protective cover may stay on during framing, but removed before final finishing. Once final finishing has been completed, the
protective cover can be used to protect appliance until final installation is complete.
Figure 6 - Combustible Finishing Material
(for 110/120V appliances)
Figure 7 - Combustible Finishing Material
(for 208/220/240V appliances)